Buy more than* S$200* and get FREE SHIPPING

Clamp Meters

Sort by:
Showing 1 - 30 of 137 Results
Show: 30 60 90
VIEW: Grid View List View
Clamp Meter
A&D
5.00(4)
61.94 SGD
ADD TO CART
Continuity Testing: Buzzer sounds about 50ohm or less, Maximum Count Number: 1999 count, Detection System: Average value rectification (MEAN), Sampling: About 3 times / second, Clamp Diameter (phi mm): About 28, Alternating Current (A): (Clamp measurements) 2/20/200/400 accuracy +/-(2.0% rdg +5 d), Functions: Peak hold function, data hold function, diode test function auto range switching, Dimensions (Width W x Depth D x Height H) (mm): 76x30x208, DC Voltage (V): 200m/2/20/200/600 Accuracy +/-(0.8% rdg +1 d), Resistance (omega): 200/2k/20k/200k/2M/20M Accuracy +/-(1.0% rdg +2 d), AC Voltage (V): 2/20/200/600 Accuracy +/-(1.2% rdg +5 d), Power: X2 AAA batteries (included), Weight (g): 200, Accessories: Test lead strap and batteries (for monitoring), instruction manual
Category Clamp Meters > AC Only
Digital multimeter with an AC/DC clamp
Kyoritsu Electrical Instruments Works
129.90 - 159.90 SGD
EMC Standard: IEC61326-1, Safety Standards: IEC610101-1 (JIS C 1010-1) excess-voltage CAT.III300V degree-of-contamination 2 IEC 61010-2-031 (JIS C 1010-2-031) and IEC61010-2-032 (JIS C 1010-2-032), Type: Digital multimeter, Accessories: 1.5 V AAA BATTERIES X 2, INSTRUCTION MANUAL
Category Clamp Meters
Digital Multimeter With An Ac/Dc Clamp
Kyoritsu Electrical Instruments Works
3.67(3)
209.90 SGD
ADD TO CART
Caution: Damage by falling impact and high temperature is not covered by warranty, Damage by falling impact and high temperature is not covered by warranty, Purpose: Current and voltage measurement of complex cables like distribution board, photovoltaic panel, alternator., Current and voltage measurement of complex cables like distribution board, photovoltaic panel, alternator., Capacitance (F): 400.0n/4.000/40.00 micro +/- 2.5 %rdg +/-10 dgt, External Form Dimensions (Length x Width x Depth)(mm): 128x92x27, Safety Standards: IEC61010-1 CAT.? 300 V, CAT.? 600V pollution degree 2 IEC61010-031, IEC61010-2-032, IEC61326, Diode Test: 2 V +/- 3.0 %rdg+/- 5 dgt open voltage: about 2.7 V, Electrical Connection Range (buzzer) (ohm): Under 30+/-25, buzzer rumbling, Continuous Opreration Time: DCV ...
Category Clamp Meters
Clamp Meter, AC-DC Current Measurement
TRUSCO
4.80(5)
189.90 SGD
ADD TO CART
Purpose: Current measurement of electrical work in the building. Current measurement of a motor vehicle., Current measurement of electrical work in the building. Current measurement of a motor vehicle., Dimensions (Width x Depth x Height)(mm): 71x37x190, Maximum Measuring Conductor Diameter (mm): 30, Detection System: Average value rectification (MEAN), Direct Current (A): 600, Maximum Display: 4000 count, Alternating Current (A): 600, Continuous Opreration Time: 190 hours, DC Voltage (V): 600, Resistance (omega): 40M, AC Voltage (V): 600, Power: X2 AAA batteries (not included), Weight (g): 220, Set Contents: Instruction manual, soft case, test leads
Category Clamp Meters > AC-DC Use
Clamp Meter
Sanwa Electric Instrument
129.90 SGD
ADD TO CART
Battery Check: Guided communication buzzer, Clamp Diameter (phi mm): 25, Alternating Current (A): 40/400, DC Voltage (V): 400/600, Resistance (omega): 400, AC Voltage (V): 400/600, Dimensions (Height H x Width W x Depth D) (mm): 193x50x28, Withstand Voltage: 3700 Vmrs or less, Cycle(Hz): (Electric current) 20-4 k / 10 k_ (Voltage) 4k/40k/400k/1M, Weight (g): About 230, Type: Clamp meter, TRUSCO Part Number: 284-8473, Accessories: Test lead (TL-88)/Cellphone case ( CDCM400) Manual
Category Clamp Meters > AC Only
Mini Cross Flow Clamp Meter
A&D
4.38(8)
139.90 SGD
ADD TO CART
Input Curret (A): 200CD/ACrms, Polarity: Automatic switching, "-" display appears when polarity is negative, Maximum Input Voltage: 500VDC/Acrms, Sampling: About 2 times/seconds, Clamp Diameter (phi mm): About 30, Battery: LR44 alkaline button batteries or SR44 silver oxide batteries x 2, Direct Current (A): 0-150.0(+/-2.0%rdg+/-3dgts), 150.1-199.9(+/-3.0%rdg+/-3dgts), Alternating Current (A): 0-150.0(+/-2.0%rdg+/-5dgts), 150.1-199.9(+/-3.0%rdg+/-5dgts)(at 50/60Hz) 0-150.0(+/-2.5%rdg+/-5dgts), 150.1-199.9A(+/-4.0%rdg+/-5dgts)(at 20 - 500Hz), Battery life (hours): About 30 (when using SR44), External Dimensions (Width (W)x Depth (D)x Height (H)) (mm): 48x20x146, Resolution Capability: 0.1 A (DC / AC), Display: 1999 Count display, Temperature Range (deg C): Guaranteed temperature/23 +/- 5 7...
Category Clamp Meters > AC-DC Use
Clamp Meter
MonotaRO
67.11 SGD
ADD TO CART
Purpose: For repairman of electric devices. For educational material of career college., For repairman of electric devices. For educational material of career college., For repairman of electric devices. For educational material of career college., For repairman of electric devices. For educational material of career college., Allowable Input: Alternating current(AC): up to 350 A (10 seconds) _x000D _ AC voltage / DC voltage: maximum 600Vrms_x000D _ Resistance: 250 Vrms (10 seconds), Accuracy: Alternating current(AC): +/-0. 2 %rdg +/- 8dgt_x000D _ Alternating current(AC): +/-2.3%rdg+/-6dgt _ Alternating current(AC): +/-1.3%rdg+/-3dgt Resistance: +/- 2 %rdg + 5 dgt, Clamp Diameter (phi mm): 40, Alternating Current (A): 30/300 To 2 (2 range auto), Resolution Capability: ALTERNATING CURRENT:...
Category Clamp Meters > AC Only
Q Snap AC Clamp Meter
Kyoritsu Electrical Instruments Works
119.90 SGD
ADD TO CART
Accuracy: alternating current: -- 20 A +/-2.0%rdg+/-5dgt (50 Hz - 1 kHz) -- 200 A +/-2.0%rdg+/-5dgt(50/60 Hz) +/-3.0%rdg+/-10dgt (40 Hz - 1 kHz), External Form Dimensions (Length x Width x Depth)(mm): 147x58.5x26, Safety Standards: IEC61010-1 (JIS C 1010-1) CAT.III 300V contamination degree 2, Auto Power-off: About 10 minitues, Measured Conductor Diameter: Maximum phi24mm, Batteries: Button cell LR-44(1.5V)x2, Response Time (seconds): About 1, Continuous Opreration Time (hours): About 120, Withstand Voltage: AC3700V FOR 1 MINUTE, Weight (g): About 100 (battery included), Measuring Range: ALTERNATING CURRENT: 20A, 200A, Accessories: 9090 (carry case), button cell LR-44x2, an operation manual
Category Clamp Meters > AC Only
Clamp Type Tester
Yokogawa Meters & Instruments
5.00(1)
129.90 SGD
ADD TO CART
Safety Standards: FITS EN61010-1, EN61010-2-03 conform, Influence of the Conductor Position: Difference between the minimum and maximum values is as follows: 2 percent thanks to 10 mm in diameter, Influence of External Magnetic Field: 400 A m of the AC magnetic field up to 0.8 A, Data Holding: Full range available, Detection System: Average value, Alternating Current (AC): (20A range) accuracy 2.0 + 7 (50 to 1 KHz ) (200A range) accuracy from 1 KHz to 2.0+5(50/60Hz)3.0+10(40 ) * Accuracy: (at 23 degree c +/- 5 degree c and 75% RH below ), +/- %rdg + dgt..'.(% reading + minimum-digit value ), Battery Life (continuous use): About 100 hours, DC Current: -, Range Switching: Manual range, Measureable Conductor Diameter (mm): Maximum of aboutphi24, Power Consumption (mA): About 1, Response Tim...
Category Clamp Meters
Clamp Meter
Sanwa Electric Instrument
4.75(4)
269.90 SGD
ADD TO CART
Clamp Diameter (phi mm): 25, Direct Current (A): 40/400, Alternating Current (A): 40/400, DC Voltage (V): 400/600, Resistance (omega): 400, AC Voltage (V): 400/600, Dimensions (Height H x Width W x Depth D) (mm): 193x50x28, Withstand Voltage: 3700 Vmrs or less, Weight (g): About 230, Type: Clamp meter, TRUSCO Part Number: 284-8481, Accessories: Test lead (TL-88)/Cellphone case ( CDCM400) Manual
Category Clamp Meters > AC-DC Use
AC Clamp Meter, Analog
Kyoritsu Electrical Instruments Works
119.90 SGD
ADD TO CART
External Form Dimensions (Length x Width x Depth)(mm): 193x78x39, Measured Conductor Diameter: Maximum phi33mm, Batteries: AA batteries R6P (1.5V) x1, Alternating Current (A): +/-3% of full scale 6/15/60/150/300 value, Frequency Range (Hz): 50 - 60, Resolution Capability: 0.2A (minimum), DC Voltage (V): +/-3% of 60V full scale value, Resistance (omega): +/-2% 1/10K of (median 25/250) scale length, AC Voltage (V): +/-3% of full scale value 150/300/600, Withstand Voltage: AC3700V / 1 minute, Compatible Standard: 2 IEC61010-2-031 2 CAT.II600V pollution degree (JIS C 1010-1) CAT.III300V pollution degree IEC61010-1 (JIS C 1010-2-31) IEC61010-2-032 (JIS C 1010-2-32), Weight (g): (Including battery) about 275, Accessories: (8901), (9097), 6Px1 pieces AA batteries, instruction manual carry...
Category Clamp Meters > AC Only
AC Digital Clamp Meter
Kyoritsu Electrical Instruments Works
4.50(2)
119.90 SGD
ADD TO CART
Caution: Damage by falling impact and high temperature is not covered by warranty, Damage by falling impact and high temperature is not covered by warranty, Purpose: For thin and ultra-light,it is convenient for measurements in complex cables., For thin and ultra-light,it is convenient for measurements in complex cables., External Form Dimensions (Length x Width x Depth)(mm): 190x68x20, Measured Conductor Diameter: Maximumphi33mm, Trunking: Below 50+/-30ohm buzzer rings, Alternating Current (AC): 40.00/400.0/1000V(3 range auto) +/- 1.4 %rdg +/- 6 dgt (50 / 60 Hz) +/-1.6%rdg+/-6dgt(45?65Hz), Resistance: 4.000/40.00/400.0/600V(4 range auto) +/- 2.0 %rdg +/- 4 dgt (0 to 400 k ohm) +/- 2.0 %rdg +/- 4 dgt (0 to 400 k ohm) Voltmeter: +/- 8.0 %rdg +/- 4 dgt, DC Voltage: 4.000/40.00/400.0/600...
Category Clamp Meters > AC Only
Mini Clamp Meter
Muti Measuring Instruments
4.75(4)
82.43 SGD
ADD TO CART
CT Overall Dimensions: phi40mm, Battery Life (continuous use): About 50, Alternating Current (A): 0 to 30.300 (2 range auto ) MINIMUM RESOLUTION RESOLUTION 0.1 A, Other Functions: VIEW OL, data hold, Dimensions (Width W x Height H x Depth D) (mm): 64x193x24, DC Voltage (V): 300 to 500 (5 range auto), Resistance (omega): 300 To 3000 (2 range auto), AC Voltage (V): 3 to 500 (4 range auto), Power: LR44 BUTTON BATTERIES X 2,with auto power off system, Weight (g): 100, Accessories: Lead tester, soft case, button cell battery
Category Clamp Meters > AC Only
Digital Multimeter With A Clamp
Custom
3.00(5)
209.90 SGD
ADD TO CART
Purpose: Measurement of electriccurrent, voltage, resistance, frequency, etc in plant and various workplaces, etc, Measurement of electriccurrent, voltage, resistance, frequency, etc in plant and various workplaces, etc, AC Voltage (ACV): Range: 660.0mV, 6.600V, 66.00V, 600.0V Resolution: 0.1mV, 0.001V, 0.01V, 0.1V Accuracy: +/-(1.5%rdg+5dgt), DC Voltage (DCV): Range: 660.0mV, 6.600V, 66.00V, 600.0V Resolution: 0.1mV, 0.001V, 0.01V, 0.1V Accuracy: +/-(1.0%rdg+3dgt), Alternating Current (ACA): Range: 66A, 120A Resolution: 0.01A, 0.1A Accuracy: +/-(2.0%rdg+5dgt), DC Current (DCA): Range: 66A, 120A Resolution: 0.01A, 0.1A Accuracy: +/-(2.0%rdg+10dgt), +/-(2.0%rdg+5dgt), Dimensions (Width W x Height H x Depth D) (mm): 81x130x24, Resistance (omega): Range: 660.0, 6.600K, 66.00K, 660.0K, 6.600M,...
Category Clamp Meters
Fork Current Tester
Kyoritsu Electrical Instruments Works
169.90 SGD
ADD TO CART
Accuracy: +/-2%rdg+/-5dgt(50/60Hz)/AC A 0 - 100.0A +/-2.0%rdg+/-5dgt/DC A 0 - 100.0A, Dimensions (Length L x Width W x Depth D)(mm): 161.3x40.2x30.3, Measured Conductor Diameter: Maximumphi10mm, Voltage Sensing: NCV: determine whether the voltage a contactless (non-covered wire-line for both naked) intermittent sound of the buzzer and display "Hi" flashes upon voltage detection, Crest Factor (CF): 2.5, Measureable Conductor Diameter (mm): Maximum phi10mm, Batteries: R03 (AAA BATTERY: UM-4 ) x 2, Maximum Display: 1049 counts, Compatible Standard: IEC61010 - OVERLOAD-VOLTAGE CAT. ? 300V POLLUTION DEGREE 2, Weight (g): About 110 (battery included), Measuring Range: AC A 0 - 100.0A DC A 0 - 100.0A, Description 2: True RMS measurements in distorted, optimized for wave Auto power OFF function, O...
Category Clamp Meters
Clamp Tester DC
Yokogawa Meters & Instruments
5.00(1)
329.90 SGD
ADD TO CART
Purpose: Electric construction and maintenance. DC power supply current measurement., Electric construction and maintenance. DC power supply current measurement., 2014 TRUSCO Published Page: 1-0955, Safety Standards: Meets EN61010-1, EN61010-2-03, Sleeve Feature: Power down in five minutes About, Influence of the Conductor Position: from the core center of the phi10mm in every position of the core within + / -2.0% rdg + /-5dgt within, Influence of External Magnetic Field: The 1A following exchange in a magnetic field of 400A / m, Data Holding: All range available, Detection System: Average value, Alternating Current (AC): Range 40A: 1.0 +4 (50/60Hz) accuracy, 2.5 +4 (20 to 1KHZ) range 300A (20 to 200A): 1.5 +4 (50/60HZ) accuracy, 2.5 +4 (20 to 1KHz) range 300A ( 200 to 300A): accuracy 3.5 ...
Category Clamp Meters
Inbred direct two way clamp meter
Kyoritsu Electrical Instruments Works
269.90 - 509.90 SGD
Category Clamp Meters > AC-DC Use
Clamp Tester
Custom
249.90 SGD
ADD TO CART
2015 Trusco Published Pages: 1 1018, AC Voltage (ACV): Range: 400V, 600V / resolution: 0.1V, 1V / accuracy: +/- (1.0% rdg + 5dgt), Range: 400V, 600V / resolution: 0.1V, 1V / accuracy: +/- (1.0% rdg +5 dgt), DC Voltage (DCV): Range: 400, 600 / Resolution: 0.1, 1 / Accuracy: +/- (0.7% rdg + 5dgt), Range: 400, 600 / Resolution: 0.1, 1 / Accuracy: +/- (0.7% rdg +5 dgt), Maximum Measuring Conductor Diameter (mm): 27, 27, Alternating Current (ACA): Range: 40,400 / resolution: 0.01, 0.1 / accuracy: +/- (2.0% rdg + 5dgt), Range: 40,400 / resolution: 0.01, 0.1 / Accuracy: +/- (2.0% rdg +5 dgt), DC Current (DCA): Range: 40,400 / resolution: 0.01, 0.1 / accuracy: +/- (2.0% rdg + 5dgt), Range: 40,400 / resolution: 0.01, 0.1 / Accuracy: +/- (2.0% rdg +5 dgt), Sampling: 3 times / sec, 3 times / sec, Bod...
Category Clamp Meters
Leak Current Measuring Clamp Meter
Kyoritsu Electrical Instruments Works
5.00(3)
449.90 SGD
ADD TO CART
External Form Dimensions (Length x Width x Depth)(mm): 185x81x32, Measured Conductor Diameter: Maximum phi40mm, Influence of External Magnetic Field: 10mA or less at the close of the state 100Aphi15mm (conductor diameter), Batteries: AAA batteries R03 (1.5V) x2, Alternating Current (A): 50/60Hz: 40/400m/400 +/-1% rdg +/-5dgt (40/400m) +/-1% rdg +/-5dgt (0 - 300) +/-2% dgt (300.1 - 399.9) WIDE: 40/400m/400 +/-2.5% rdg +/-10dgt (20Hz - 1kHz) +/-1% rdg +/-5dgt (50/60Hz) (40/400m) +/-2.5% rdg +/-10dgt (40H, Response Time (seconds): About 2, Frequency Range (Hz): 20 - 1K, Continuous Opreration Time (hours): (About 10 minutes auto power off) for about 24 hours, Resolution Capability: 0.01mA (minimum), Withstand Voltage: AC3700V / 1 minute, Compatible Standard: IEC61010-1 2 IEC6101...
Category Clamp Meters > AC Only
ACCD Clamp Meter
Kyoritsu Electrical Instruments Works
329.90 SGD
ADD TO CART
Accuracy: Alternating current + / -1% rdg + /-4dgt (0 to 40A) (50/60Hz) + / -2.5% rdg + /-4dgt (0 to 40A) (20Hz to 1kHz) + / -1.5% rdg + /-4dgt ( 20 to 200A) (50/60Hz) + / -2.5% rdg + /-4dgt (20 to 200A) (20Hz to 1kHz) + / -3.5% rdg (200 to 300A) (50/60Hz) + / -4% , Auto Sleep Function: About 5 minutes, External Form Dimensions (Length x Width x Depth)(mm): 147x59x25, Safety Standards: IEC61010-1 2IEC61010-2-032 (JIS C 1010-1) CAT.III 300V Pollution degree (JIS C 1010-2-32), Measured Conductor Diameter: Maximum phi24mm, Batteries: Button battery LR-44 (1.5V) x2, Response Time (seconds): About2, Continuous Opreration Time (hours): About10, Resolution Capability: Minimum 0.01A (2 range of auto 40A/300A), Withstand Voltage: 1 minute AC3700V, Weight (g): About 100 (including batteries), Measur...
Category Clamp Meters > AC-DC Use
Q-snap AC leak clamp meter
Kyoritsu Electrical Instruments Works
5.00(1)
429.90 SGD
ADD TO CART
Accuracy: Alternating current (50 / 60 Hz): +/- 3.0 %rdg + 5 dgt (20mA/200mA/100 A) +/- 5.0 %rdg + 5 dgt (200 A) Alternating current (WIDE): +/- 2.0 %rdg +/- 4 dgt (20mA/200mA/100 A) (50 / 60 Hz) +/- 5.0 %rdg + 6 dgt (20mA/200mA/100 A) ( 40 Hz-400 Hz ) +/- 5.0 %rdg, External Form Dimensions (Length x Width x Depth)(mm): 149x60x26, Safety Standards: IEC61010-1 (JIS C 1010-1) CAT.III 300V Degree-of-contamination: 2 IEC 61010-2-032 (JIS C 1010-2-32), Auto Power-off: About 10 minitues, Measured Conductor Diameter: Maximum phi24mm, Batteries: Button cell LR-44(1.5V)x2, Response Time (seconds): Approx. 2, Continuous Opreration Time (hours): About 15, Resolution Capability: 3 Ranges, sensitive and stable view. Minimum 0.01mA to 199.9 A, Withstand Voltage: AC1000V FOR 1 MINUTE, Weight (g): About 1...
Category Clamp Meters > AC Only
Leak Current Measuring Clamp Meter
Kyoritsu Electrical Instruments Works
5.00(1)
429.90 SGD
ADD TO CART
Caution: Damage by falling impact and high temperature is not covered by warranty, Damage by falling impact and high temperature is not covered by warranty, Purpose: Ideal for electric leak management of shops and buildings, Ideal for electric leak management of shops and buildings, External Form Dimensions (Length x Width x Depth)(mm): 185x81x32, Measured Conductor Diameter: Maximum phi40mm, Influence of External Magnetic Field: In an approaching state of 100Aphi15mm (Conductor diameter)below 10mA, Batteries: AAA batteries R03(1.5V) X 2, Alternating Current (A): 50/60Hz:40/400m/400 +/-1%rdg+/-5dgt(40/400m) +/-1%rdg+/-5dgt(0 - 300) +/-2%dgt(300.1 - 399.9) WIDE:40/400m/400 +/-2.5%rdg+/-10dgt(20Hz - 1kHz) +/-1%rdg+/-5dgt(50/60Hz)(40/400m) +/-2.5%rdg+/-10dgt(40Hz - 1kHz) +/-1%rdg[+, Response ...
Category Clamp Meters > AC Only
Mini Clamp Leaker
Muti Measuring Instruments
329.90 SGD
ADD TO CART
2014 TRUSCO Published Page: 1-0957, Leakage Current (mA): 200, Maximum Measuring Conductor Diameter (mm): 33, Detection System: Average value rectification (MEAN), Maximum Display: 1999 count, Alternating Current (A): 150, Dimensions (Width W x Depth D x Height H) (mm): 54x20x155, Power: (LR44) x2 or button-type alkaline batteries (included), Weight (g): 85, TRUSCO Part Number: 321-4265
Category Clamp Meters > AC Only
Leak current measuring clamp meter
Kyoritsu Electrical Instruments Works
669.90 SGD
ADD TO CART
Caution: Damage by falling impact and high temperature is not covered by warranty, Damage by falling impact and high temperature is not covered by warranty, Purpose: Excellent performance measurement of three-phase batch by using large-diameter core, Excellent performance measurement of three-phase batch by using large-diameter core, External Form Dimensions (Length x Width x Depth)(mm): 250x130x50, Measured Conductor Diameter: Maximum phi68mm, Batteries: 006P(9V)x1, Alternating Current (A): 50/60Hz:200m/2/20/200/1000 +/-1.5%rdg+/-2dgt(200m/2/20) +/-2%rdg+/-2dgt(200, 0 - 500) +/-5%rdg(50/60Hz)(501 - 1000) WIDE:200m/2/20/200/1000 +/-1%rdg+/-2dgt(50/60Hz)(200m/2/20) +/-1.5%rdg+/-2dgt(50/60Hz)(200, 0 - 500) +/-5%rdg(50/60Hz)(501 - 1000), Frequency Range (Hz): 40 - 1K, Continuous Opreration Ti...
Category Clamp Meters > AC Only
Clamp Meter
Kyoritsu Electrical Instruments Works
619.90 SGD
ADD TO CART
Caution: Damage by falling impact and high temperature is not covered by warranty, Damage by falling impact and high temperature is not covered by warranty, Purpose: With external power source terminal. For long term leakage current monitoring., With external power source terminal. For long term leakage current monitoring., External Form Dimensions (Length x Width x Depth)(mm): 209x96x45, Measured Conductor Diameter: Maximum phi40mm, Resistance: 200.0ohm + / -1.5% rdg + /-5dgt, Batteries: 006P(9V)x1, Alternating Current (A): 50/60:20/200m/2/20/200/500+/-1.5%rdg+/-5dgt(20/200m/2)+/-2%rdg+/-5dgt(20/200)+/-2.5%rdg+/-5dgt(500)WIDE:20/200m/2/20/200/500+/-1%rdg+/-3dgt(50/60Hz)(20/200m/2)+/-1.5%rdg+/-3dgt(50/60Hz)(20/200)+/-2%rdg+/-3dgt(50/60Hz)(500), Frequency Range (Hz): 40 to 400, Continuous O...
Category Clamp Meters > AC Only
Clamp Tester
Yokogawa Meters & Instruments
489.90 SGD
ADD TO CART
2014 TRUSCO Published Page: 1-0955, Maximum Measuring Conductor Diameter (mm): 33, Detection System: Rectifier effective value of true (RMS), Direct Current (A): 1000, Maximum Display: 3999 count, Alternating Current (A): 600, Dimensions (Width W x Depth D x Height H) (mm): 91x40x210, DC Voltage (V): 600, Resistance (omega): 4000, AC Voltage (V): 600, Power: (6F22) x1 this stacked 9V battery (included), Weight (g): 450, TRUSCO Part Number: 338-0327
Category Clamp Meters
Clamp Meter
Sanwa Electric Instrument
129.90 SGD
ADD TO CART
Conductor Size (mm): 10x50, Clamp Opening Diameter (phi mm): 36, Alternating Current (A): 6/15/60/150/600, Frequency Characteristics: 50/60Hz, Temperature: -10 to +200deg C, DC Voltage (V): 60, Resistance (omega): 1k/100k, AC Voltage (V): 150/300/600, Dimensions (Height H x Width W x Depth D) (mm): 221x97x43, Withstand Voltage: 5550VAC, Weight (g): 420, Type: Clamp Meters
Category Clamp Meters > AC Only
Digital Clamp Meter
Sanwa Electric Instrument
2.00(1)
219.90 SGD
ADD TO CART
Voltage Frequency (Hz): 660.0/6.666k/66.00k/100k, Alternating Current (A): 66.00/660.0, Outside Dimension (Height x Width x Depth) (mm): 208x69x38, DC Voltage (V): 600.0, Resistance (omega): 660.0, AC Voltage (V): 600.0
Category Clamp Meters > AC Only
Digital Clamp Meter
Sanwa Electric Instrument
5.00(1)
319.90 SGD
ADD TO CART
Purpose: Power and facility instrument maintenance, Power and facility instrument maintenance, Trunking: Buzzer sounds About 40ohm or less, Clamp Diameter (phi mm): About30, Direct Current (A): 66.00/660.0, Alternating Current (A): 66.00/660.0, Outside Dimension (Height x Width x Depth) (mm): 208x69x38, DC Voltage (V): 600, Resistance (omega): 999.9, AC Voltage (V): 600, Weight (g): About260, Accessories: Test leads (TL-23a) / Carrying Pouch (C-DCM660) / manual
Category Clamp Meters > AC-DC Use
DIGITAL AC/DC CLAMP METER
Custom
476.74 SGD
ADD TO CART
AC Voltage (ACV): Range: 1.3-750.0V / resolution: 0.1V, 1V / accuracy: +/- (0.9% rdg + 3dgt) 50-60Hz, + / - (1.5% rdg + 3dgt) 61-500Hz, DC Voltage (DCV): Range: 2.1-1000, -0.7--1000 / resolution: 0.1, 1 / Accuracy: +/- (0.3% rdg + 2dgt), Maximum Measuring Conductor Diameter (mm): 35, Alternating Current (ACA): Range: 0.9-600.0 / Resolution: 0.1, 1 / Accuracy: +/- (1.5% rdg + 5dgt) 50 / 60Hz, DC Current (DCA): Range: 0.9-600.0 / Resolution: 0.1, 1 / Accuracy: +/- (1.5% rdg + 5dgt) 50 / 60Hz, Diode Test: Range: 0.4-0.8V / resolution: 0.1V / accuracy: +/- (0.9% rdg + 3dgt), Sampling: 5 times / sec, Body Dimensions (Width x Depth x Height) (mm): 90x50x215, Resistance (omega): Range: 0.0-9999 / Resolution: 0.1, 1 / Accuracy: +/- (0.9% rdg + 2dgt), Power: 9V angle type battery (006P, etc. 6F66,6...
Category Clamp Meters

1 2 3 4 5 Next